Circuit And Load Protection

Browse technical resources about OEM fiber optic solutions for data centers, telecom, and industrial automation.

  • Relay protection KCT negative

    Relay protection KCT negative

    The various protective functions available on a given relay are denoted by standard. For example, a relay including function 51 would be a timed overcurrent protective relay. An overcurrent relay is a type of protective relay which operates when the load current exceeds a pickup value. It is of two types: instantaneous over current (IOC) relay and definite time overcurrent (DTOC) relay.


  • Fireproof cable tray fire protection time

    Fireproof cable tray fire protection time

    30 minutes hydrocarbon fire protection to cable trays carrying control cable wiring. The FireMaster® cable tray wrap consists of FireMaster® Marine Plus blanket fully encapsulated in aluminium foil supplied and in a roll form. Fire resistance testing involves different methods to evaluate safety performance. The sample is exposed to direct flames. Fire Rating: Up To EI120 (240 minutes integrity, 120 minutes insulation) Fire Attack: Both Sides Cable Load (max): 24kg/lm 40 Year. Where cables pass through shafts, walls, slabs, or enter electrical panels or cabinets, openings shall be tightly sealed with firestopping materials in accordance with design requirements. Process flow: reserved openings → busway installation → distribution box positioning and installation →. Our tested solutions for cable fire protection can delay the spread of fire in order to minimise the damage sustained. 7 products are successfully used to protect cables in high-rise buildings. The resulting barrier retards the transmission of smoke, fire, and toxic gases from spreading between adjacent rooms and floors for the rated time period.

    [PDF Version]
  • Relay protection rotation mode

    Relay protection rotation mode

    The various protective functions available on a given relay are denoted by standard. For example, a relay including function 51 would be a timed overcurrent protective relay. An overcurrent relay is a type of protective relay which operates when the load current exceeds a pickup value. It is of two types: instantaneous over current (IOC) relay and definite time overcurrent (DTOC) relay.


  • GC660 Microcomputer Relay Protection Tester

    GC660 Microcomputer Relay Protection Tester

    The main control board is DSP + FPGA architecture, 16 bit DAC output, generates high - density sine wave 2000 points each circle to fundamental wave, which greatly improve the wave quality and the accuracy of the test instrument. Classic Windows XP operating interface, friendly. Protection relays play a key role in modern energy systems. Therefore, they must work reliably at all times. TEST-630 relay test kit is a the most advanced six-phase relay test set. Protection relay tester which offers all the characteristics and functions needed for protective relay testing, in a manual or automatic mode, designed for maximum efficiency, flexibility and simplicity, with the required accuracy and performance to test any kind and type of relays in all. HUAZHENG Electric Manufacturing (Baoding) Co., Ltd is established in year of 2008, located at Baoding city, Hebei province, China. Main Product: transformer oil test series, high voltage.

    [PDF Version]
  • What is relay protection XP01

    What is relay protection XP01

    The objective of relay protection is to quickly isolate a faulty section from both ends so that the rest of the system can function satisfactorily. The functional requirements of the relay:.


  • Working principle of optical path protection module

    Working principle of optical path protection module

    Path protection in is an end-to-end protection scheme used in circuits in different to protect against inevitable failures on ' network that might affect the services offered to end customers. Any failure occurred at any point along the path of a circuit will cause the end nodes to move/pick the traffic to/from a new route. Finding paths with protection, especially in elastic optical networks, was considered a difficult problem, but an efficient an.